Product Type > Pressure Sensing > KL-95   

Pressure Transducer for Ultra-Pure Water

The KL-91 is a pressure transducer suitable for use in monitoring
pressure of various high-purity fluids. The superior design provides
for minimal “dead volume” which reduces the potential for
contamination of the measured fluid. The KL-91 is available in two
construction type: inline or insertion. The body construction meets
IP-65 requiremnents and EMC resistant the level of CE.


Features
• ± 1 % full-scale accuracy
• All PFA/PTFE wetted part construction and PTFE coating on Alumina Sensor
• No 'O'-ring seals or fill fluids
• Choice of end fitting: Flare, Pillar, 20S, or Tube

Applications
• High-purity DI water, and CMP slurry
• Filtration condition monitoring
• General pressure monitoring

Standard Specifications
Measurement Range -14 to 75 psig
Maximum Allowable Over Pressure 120 psi
Accuracy* ± 1% F.S
Output Signal 0-10VDC 4-20mA, 1-5 VDC, 0-5VDC
Supply Voltage 24VDC 15-24VDC
Operating Temperature 10° to 80°C / (50° to 176°F)
Applications High-purity DI water, and CMP slurry
Process Connection - Sizes 1/4", 3/8", 1/2", 3/4", 1"
Process Connection - Types Tube, Flare, Pillar, 20S
Enclosure Protection Ip 65 Compatible
Construction Materials Wetted parts - PFA/PTFE, Non Wetted - Polypropylene

Product Data Sheet

 
Malema Headquarters (Florida):
Malema California:
Malema Korea:
Malema Singapore:
 +1 561-995-0595 or 1-800-637-6418
 +1 408-970-3419
 +82 2 3473 0786
 +65 6482 3533
malema@malema.com