Flow direction: Available for all flow directions
Measuring range:0,8 m3/h … 1600 m3/h H2O; 45 Nm3/h … 24000 Nm3/h air
Accuracy:DP65 model +-2,5% f.s. (+-1,6% f.s. on request); DP500 model +-4,0% f.s.
Connections:DP65 model DN40 … DN300 between flanges;DP500 model DN250 … DN500 flanged; Standard flange connection according to DIN 2501. Others on request.
Materials: Flow tube -Coated steel, EN 1.4404 (SS 316L); Housing in aluminium (Available in SS 316L or PP on request)
Indication: Local indication
Options:1 or 2 adjustable switches (micro-switch or inductive sensor); Design for high pressure on request; Electronic transmitter with 4-20 analog output for safe or hazardous area (Ex ia IIC T4 or T6 protection, ATEX certified); HART ™ protocol on request; Local volume totalizer. Remote volume totalizer by means of pulse output (not available for Ex transmitters)
Set Point Accuracy |
DP65:±2.5% , DP500: ±4% |
Materials |
Polyamide coated steel (Standard), SS-316L |
Connection Sizes |
:1.5” to 20” (DN40 to DN500) |
Flow Ranges |
Water |
0.8 m³/h up to 1600 m³/h ( 3.5 to 7000 GPM) |
Air |
45 Nm³/h up to 24000 Nm³/h ( 26.5 to 14000 SCFM) |